Loading
  • Catalogue
  • Catalogue

1 Pages -   1   

The control and maintenance unit is built in a 20ft container which is divided into two compartments, the control compartment and the maintenance compartment. <b>Control compartment</b> The control compartment is equipped with two desks which both have full control over one ROV. It's also possible to use two ROV's with one control unit. Each desk is equipped with the following: - Stainless steel panel - 3 HDD/DVD recorders - ROV LARS surveillance monitor - ROV camera monitors - Saab Seaeye surface control unit - Tritech sonar monitor - Tracklink Navigator monitor and computer - Tritech Sonar computer - One way communication to ROV LARS - ROV hand control unit - ROV hydraulic manipulator controller - UPS (Uninterruptible Power Supply) - PSU (Power Supply Unit) <b>Maintenance compartment</b> The maintenance compartment can store up to two Saab Seaeye Cougar XT compacts and two complete stainless steel tether winches. It's equipped with a handy winch to take the ROV's and winches out of the compartment with ease. In the two storage closets is enough storage space for all the spare and maintenance parts. A collapsible table is mounted against the wall, it can be used when you need extra space for maintaining the ROV's. When there is no need for the table you simply collapse the table against the wall and you've got your space back again.
 
POM-LR 1800 CONTAINERIZED MIXED GAS/AIR DIVE CHAMBER - Lloyd's RS certified - 20ft Container (ISO) - DDC IMCA compliant diam. 1800mm - 16 cilinder airbank Guidance Codes and Standards - IMCA D023: DESIGN for Surface Orientated (Air) Diving Systems - IMCA D037: DESIGN for surface supplied mixed diving systems, Jan. 2006 - IMCA D014: International Code of Practice for Offshore Diving - Lloyd's Rules and Regulations for Offshore Structures - EN13445 - Unfired Pressure Vessels: European rules for the design, fabrication, and inspection of pressure vessels 20ft Container - Standard Class A 20ft ISO Container - Insulated - Personnel sea-door with integrated window in longside container - Stainless steel penetrator panel for gas inward connections and electricity socket Double Lock DDC1800 - Built under the supervision of Lloyd's Surveyors - CE Declaration of Conformity - Lloyd's certified conform Lloyd's Rules and Regulations for Offshore Structures - 10 Bar working pressure - Folding seat in entry lock - 2 diver air/oxygen distribution panel in entry lock - Internal LED lighting in entry lock - Bullhorn 2 way communicator in entry lock - 3 Folding benches in main lock - 4 diver air/oxygen distribution panel in main lock - Internal LED lighting in main lock 2x - Bullhorn 2 way communicator in main lock - 1x Camera in main lock - 1x Camera in entry lock DDC Control panel - Amcom II double lock chamber communication system - Air & Oxygen distribution panel mounted on the outside - Pressure/depth monitoring gauges, 0.25% acc. - Oxygen content analyser point in supply line - 1x Video screen (split screen for two cameras) Electricity System - 400V - 50 Hz, 32 amp and 5 pins ( 3 fase + zero + earth ) - 32Ampere connection for the entire container, inside container - 240V AC single-phase system taken of the 380V for light and electrical sockets - 3x container Light - Earth leakage strip Gas System - HP Air bank including 16x 50ltr cylinder & Manifold - Complete tubing system Miscellaneous - 2x Fire extinguisher in container - Manuals - Pommec & Lloyd's RS certificates Options (* needed to comply to IMCA regulations); - BIBS* - Caisson gauge in main lock* - Sound powered phone* - Hyperbaric fire extinguisher in Main Lock* - Hyperbaric fire extinguisher in Entry Lock - Digital Oxygen analyser* - BA set with cylinder for operator* - Chamber Data Recording System - Video system - Fire retardant bedding - Climate control system both possible to be used as a heater or air-conditioning - DNV Offshore container instead of standard container
DIVECONTAINER NITROX 20" Specifications container; - Standard ISO 20" container with CNC plate - Divided in 2 compartments (Compressor etc. & Controls) - Insulated with 4cm thick sandwich panels - Walk in door steel at container end in "controlroom" - Window in containerwall at "controlroom side" (ca 1,25 x 0,9 mtr) - Special hatches for protecting the window during transport and storage - Two special connection boxes in container wall for electricity and gas - Two stainless steel ventilation grids in container wall at "compressorside" Further equiped as follows; Compressor compartment; - LP compressor Alup, SCK 25-10, Silent, 13 Bar - LP bank, 16 Bar, 500 Ltr - 4 piece air filtration set Parker - HP compressor silent, L&W 450 ES, 200 Bar, semi automatic, 4x filling hose - 6x 50 ltr industry cylinder, 200 Bar, air, Lloyd's certificated - 6x 50 ltr industry cylinder, 200 Bar, nitrox, Lloyd's certificated - Mixmaster L&W Nitrox Membrane - Oxygen analyzer - Heat exchanger and chiller - Two umbilical storage brackets mounted on opening container doors Controlroom; - Worktable with stainless steel controlwall for mounting the controlpanel, monitors, etc. - 3 diver controlpanel Pommec - 3 diverradio Amcom with wireless tender option - 1x wireless headset for Amcom wireless radio - 3x LCD monitor - 3x DVD recorder - 1x table - 4x chair - 1x Steel closet ca 1,95 x 0,95 x 0,45 Mtr - 2x heating - 2x fire extinguisher General; - Complete electrical system including lamps, switches, cables, fuses, trafo etc. - Complete air/nitrox tubing - Lloyd's / IMCA certificate
 
POM450 NITROX-CONTROL OFFSHORE CONTAINER 1. Applicable Guidance Codes & Standards - IMCA D023 Rev.1 : DESIGN for surface orientated (air) diving systems - IMCA D048 : Surface Supplied Diving Operations using Nitrox - IMCA D014 Rev.1 : International Code of Practice for Offshore Diving - Lloyd’s Register : Offshore rules - DNV 2.7-1 / EN12079 Container 2. POM450 Nitrox-Control Container 2.1. POM450 Machinery & Controlroom - 20ft Offshore Container - Divided in 2 compartments (Compressor etc. & Control room) - Isolated with 4cm thick sandwich panels - Walk in door at container end in "control room" - Window in container wall at "control room side" (ca 1,25 x 0,9 mtr) - Special hatches for protecting the window during transport and storage - Two stainless steel ventilation grids in container wall at "compressor side" - Special compartment with barred fence door on the outside for the Nitrox cylinders 2.2. 20 ft Container - 20ft Container (Standard ISO or DNV 2.7-1 / EN 12079 certified) - Insulated - Personnel sea-door with integrated window in container - Window in container wall at "control room side" (ca 1,25 x 0,9 mtr) - Special hatches for protecting the window during transport and storage - Stainless steel penetrator panel for gas inward connections and electricity socket - Deluge sprinkler system with water outlets above the viewports 2.3. Electricity system The complete unit will need more or less 50 Kw input. - 400Vac / 50Hz, 3 phase + neutral + protective earth - 125A connector - Stainless steel switch box - Trafo - Fuses - Power fan - Lighting and emergency lighting - Heating (Airconditioning optional) - Etc. 3. Machinery 3.1. Power class screw LP compressor, SCK 40-13 - 13 Bar - Motor power kW/Hp = 30/40 - Super sound isolation - Energy-saving operation by means of sensor-controlled "intelligent" microprocessor control system 3.2. High performance ADQ serie refrigerant dryer - Highly efficient - High profitability and operating reliability at inlet temperatures up to +60°C and a pressure dew point of +3°C make them a convincing proposition. - Volumatic flow rate 180 m3/h - 13 Bar 3.3. 4-piece air filtration set Parker 3.4. Mixmaster L&W Nitrox Membrane The Mixmaster produces nitrox mixtures of between 28 and 40% oxygen with a delivery rate of up to 800 litres per minute (dependent on the LP compressor capacity and the inlet pressure). 3.5. LP bank, 16 Bar, 500 Ltr 3.6. HP compressor silent, L&W 450 ESII, 232 Bar - Electro motor (E-Motor / 400V / 3 Phase / 50 Hz) - 11kW (13,5kW start-up) - Air cooled piston compressor - Capacity [l/min] / [Nm³/h] / [cfm]: 450 / 27.0 / 15.9 3.7. HP air & HP Nitrox buffer All HP storage will be located in a suitable place where there is a minimal risk of damage occurring. - Special compartment with barred fence door on the outside for the storage of 6x 50ltr Nitrox cylinders - Specially manifolded for supply of the control panel. - 6x 50ltr air cylinders, specially manifolded for supply of the control panel. * All cylinders will be colour coded and marked with the name and chemical symbol of the contents in accordance with IMCA D 043 * Oxygen (or mixes containing over 25% oxygen) must be stored in the open and well clear of any fire hazards. 3.8. Oxygen analyser after the Nitrox membrane 3.9. Umbilical storage Two umbilical storage brackets mounted on opening container doors, with your own logo! 4. Control room Worktable with stainless steel control wall for mounting the control panel, monitors, etc. 4.1. 3 diver + Habitat Nitrox/Air Control panel Complete with pneumometers (depth gauges), HP air supply, max 200 Bar, LP Nitrox supply, manometers, Oxyen analysers, Certificate, etc. * Accessible from the backside for maintenance and checks 4.2. 3 diver radio Amcom complete with wireless tender option, Complete with wireless headset 4.3. 3 diver video system, Complete with Monitors, recorder etc. 4.4. Deck video system, Together with CCTV, 2 camera’s + bracket on the container + monitor with splitscreen 4.5. Audio blackbox A recording system will be fitted to record all communications between divers and supervisor with possibilities of playing back the recording after the dive in order to check satisfactory quality. This recording system will be fed from the UPS to ensure continued operation for at least 30 minutes in the event of loss of main power 4.6. Intercom system Needed if diving is taking place from a vessel as there should be both primary and secondary means of communication between dive control and the bridge. The primary link must be hard wire, immediately available and unable to be interrupted. One of these links must be able to operate without the need for external power supply (secondary can be VHF for example) 4.7. UPS for monitoring system Back-up power source for diver monitoring system to ensure continued operation for at least 30 minutes in the event of loss of main power. 4.8. BA set for Supervisor / Operator Complete with Mask, Cylinder, Backpack, headset and speaking membrane in the mask 4.9. Penetrating plate welding Dedicated penetrator plate through the container wall with connectors on both sides for 2 pair of welding cables 4.10. HPU on of switch on the control panel (Sofar just a simple switch, if extra electric changes need to be made additional costs will be charged) 5. Documentation & Certificates The System comes with a complete set of documentation, consisting certificates, manuals, design approvals etc. 5.1. Documentation The following documentation is delivered with the system; - Instruction manual - IMCA DESIGN Detail Sheets - Electronic & Flow Diagrams - Etc. 7.2. Certificates
CONTAINER COMPRESSOR & GASBANKS CONFORM IMCA. We've experienced that every customer has it's own unique desires when it comes to this kind of equipment. Of course everything can be build according to your personal requirements, according to IMCA regulations and if necessary to other regulations. Below you will find an example of an aircontainer system that is completly according IMCA. - Specially adapted container 20 feet &nbsp;&nbsp;* 1 side closed for compressors &nbsp;&nbsp;* 1 side semi-open for ventilation for the gasbanks - Complete electricity system - LP Compressor &nbsp;&nbsp;* ± 1300 lpm &nbsp;&nbsp;* 16 BAR - LP gasbank &nbsp;&nbsp;* 900 Ltr - Compressor LW HP 570 lpm &nbsp;&nbsp;* 300 BAR - Closet for storage of filters and other parts - 2x cylinderrack with 8 industrial bottles 50 ltr for AIR diving &nbsp;&nbsp;* 300 BAR &nbsp;&nbsp;* Devided in 3 different lines for HP panel connection - 1x cylinderrack with 8 industrial bottles 50 ltr for 50/50 MIX diving &nbsp;&nbsp;* 200 BAR &nbsp;&nbsp;* Devided in 3 different lines for LP panel connection &nbsp;&nbsp;* Each line has its own regulator - 1x cylinderrack with 16 industrial bottles 50 ltr for OXYGEN &nbsp;&nbsp;* 200 BAR &nbsp;&nbsp;* Devided in 3 different lines for LP panel connection &nbsp;&nbsp;* Each line has its own regulator - 2x cylinderrack with 8 industrial bottles 50 ltr for DDC AIR &nbsp;&nbsp;* 300 BAR - 1x cylinderrack with 16 industrial bottles 50 ltr for DDC OXYGEN &nbsp;&nbsp;* 200 BAR &nbsp;&nbsp;* Regulator - Tubing, manifolds, valves etc. complete to connect everything (every bottle has its own valve) - HP & LP, oxygen etc. hoses to connect this system to the control & DDC container - Lloyd's certificate - Etc.
 
CONTROL & DDC CONTAINER CONFORM IMCA. We've experienced that every customer has it's own unique desires when it comes to this kind of equipment. Of course everything can be build according to your personal requirements, according to IMCA regulations and if necessary to other regulations. Below you will find an example of a control & DDC container that is completly according IMCA. - GENERAL &nbsp;&nbsp;* Container 20 feet isolated and adapted &nbsp;&nbsp;* Doors on both sides &nbsp;&nbsp;* Closed closets (2x) &nbsp;&nbsp;* Complete electrical system &nbsp;&nbsp;* Walk-in door &nbsp;&nbsp;* Window &nbsp;&nbsp;* Airconditioning &nbsp;&nbsp;* Working table with stainless steel backwall over the complete width for mounting the controlpanel etc &nbsp;&nbsp;* 2 umbilical supports &nbsp;&nbsp;* Security breathing apparatus for the DDC supervisor &nbsp;&nbsp;* Extinguisher &nbsp;&nbsp;* Lloyd’s certificate &nbsp;&nbsp;* Etc - Stainless steel backwall (easily accessible from outside for maintenance, etc.) &nbsp;&nbsp;* 2 diver controlpanel air, mix and oxygene &nbsp;&nbsp;* 2 diverradio Amcom &nbsp;&nbsp;* 2 diver video system with monitors and harddisc recorders &nbsp;&nbsp;* Oxygen analyser (2x) &nbsp;&nbsp;* CO analyser (2x) &nbsp;&nbsp;* LP alarm for the umbilicals (2x) &nbsp;&nbsp;* Etc. - DDC 1500 x 3600, 6 BAR &nbsp;&nbsp;* Medical lock &nbsp;&nbsp;* Viewports (3x) &nbsp;&nbsp;* Airpanel complete for both locks &nbsp;&nbsp;* Oxygenpanel complete for both locks &nbsp;&nbsp;* Oxygen analyser &nbsp;&nbsp;* Oxygen BIBS with overboard dump (4x) &nbsp;&nbsp;* Heating in the main lock &nbsp;&nbsp;* Chamber communicator &nbsp;&nbsp;* Hyperbaric fire extinguisher &nbsp;&nbsp;* Sound powered phones 3x (1x ext, 2x int.) &nbsp;&nbsp;* Pneumogauge in the main lock &nbsp;&nbsp;* Video system &nbsp;&nbsp;* Etc.
DiveScan is an air diving data recording system for surface supplied divers. The system records the depth and time profile of divers while in the water and in a surface recompression chamber. <b>Principle of operation</b> The system records the diver's depth using a diver worn pressure transmitter that connects through the diver’s umbilical to an interface located on the surface. The chamber locks are also fitted with pressure transmitters that connect to the same interface so that any therapeutic recompression is also recorded. The interface connects to a PC compatible computer’s Ethernet port. The computer runs the DiveScan software program that reads the pressure from the transmitters and in turn displays the diver’s depths readings on screen and logs the data to a Microsoft Access compatible data file. <b>Software details</b> The software interrogates the interface every second for the pressure data and records any change along with a time stamp in the database. The database is automatically archived at midnight every day and a one hour overlap is automatically added to each 24 hour file to provide data continuity. The depth information is presented numerically and graphically on screen. <b>Features</b> As well as measuring the diver's depths and recording them the software offers a number of useful additional features: - Dive log - Session log - Dive tables - Diver tracking - Max Depth alarms - Sensor Signal integrity monitoring - Replay
 

1 Pages -   1